Guangdong Zecheng Intelligent Technology Co., Ltd

quentin@zecheng.com.cn

86-0769-39020536

Rumah> Blog> Application of Intelligent Access Control System in Bank Linkage Interlocking Door

Application of Intelligent Access Control System in Bank Linkage Interlocking Door

June 22, 2022
Ministry of Public Security
1. According to the Ministry of Public Security and industry documents: banks must set up linkage interlocking door management. These documents include the "People's Republic of China Public Safety Industry Standards" (GA 38-2004), "Bank Business Location Risk Level and Protection Level Regulations" (GA 38-1992), "People's Republic of China Financial Industry Standard Bank Vault" (JR /T 0003-2000)
2. In response to the regulations of the Ministry of Public Security and the head office of the banks, “the treasury and the business hall should be equipped with double doors, that is, a metal security door should be added outside the treasury and the business hall. Two locks are installed on the security door, and the two keys are guarded by the unit. And the warehouse staff are responsible for opening and closing, and mutual supervision and mutual restraint." (See "Interim Provisions on Financial Institutions and Treasury Security Protection").
Bank internal and external analysis
Criminals outside the bank usually resort to violent means to rob the bank's business halls and treasury by holding, forcing bank employees or directly using blasting. The occurrence of robbery cases has caused the bank’s economy to be damaged. Secondly, it has seriously threatened the personal safety of bank staff, and the bank’s security reputation has been damaged. At present, domestic banks are generally decentralized management of business outlets throughout the country. There is no unified, real-time, and effective networked management mechanism that centralizes the decentralized management. In this way, the superior leaders of the bank are not able to immediately understand the specific trends of the employees of the branches under their jurisdiction and the actual operation of the outlets, so that the internal economic actions of the banks can be multiplied.
Bonn name lock series: Israel MUL-T-LOCK Moodyshi security door, lock picture news
The benefits of implementing bank linkage interlocking door intelligence
Internal control
The bank linkage interlocking door intelligent management system requires all employees to use the credit card or fingerprint for identity authentication. If an employee leaves the post or leaves the post within the specified time, the system will generate an alarm, thus eliminating the possibility of bank employees carrying money. Sex. In addition, because the bank linkage interlocking door intelligent management system is well-designed, detailed and stable and efficient, its own impeccable security has greatly reduced the external crime rate of robbery, restraint, coercion, and follow-up, effectively ensuring the bank. The personal safety of the employees.
Double door interlock
After adopting the bank linkage interlocking door intelligent management system, all bank employees must go through the strict identity authentication when they enter the bank vault or business hall. If the identity authentication fails, the employee can not enter the door of the vault or business hall, and the system also An alarm signal will be generated, and the operation process of the two-door interlock system is as shown in the figure.
Moreover, when bank employees are under the coercion of criminals, they can generate alarm signals through the control host, and the relevant personnel of the bank can take emergency measures after receiving the alarm signal, which can effectively protect the personal safety of the bank employees.
Intelligent management
The bank linkage interlocking door intelligent management system meets the requirements of high security of bank vaults and business halls. From the previous manual control of the vault and the business hall door, the smart access control controller controls the vault and the business hall door, which reduces the possible crime rate to a minimum.
The bank linkage interlocking door intelligent management system is easy to operate, and the operator can complete the setting with the click of a button; the system software interface is friendly, the software is powerful, and various switch door records and alarm records are recorded in detail, which is convenient for future inquiry.
How to implement the intelligentization of bank linkage interlocking doors
The specific implementation process is as follows:
※Into the business hall or treasury personnel, the smart card + fingerprint method is used to carry out the entry control management;
※Incoming and outgoing personnel can enter and exit the vault door with multiple legal cards at the same time, and the fingerprints of the supervisors and leaders. All personnel entering the business hall must swipe their cards or input fingerprints. When the card is lost or the personnel is transferred, the card is cancelled by the system. Once someone uses the illegal card, the system immediately alarms;
※All credit card and fingerprint authentication records are saved; if an employee does not swipe or input fingerprints within the specified time, the system will generate an alarm message to ensure the safety of bank employees and the safety of bank property;
※ According to the specific use of personnel, the authority level is categorized, for example, the first three people swipe the card request, and the latter person's fingerprint determines the door to open the vault. Wait for the fingerprint to confirm that there is a prompt tone, the fingerprint reading is valid during the process of prompting the sound, and the card needs to be swiped again after the timeout.
※When power is cut off, there are more than 30,000 power-off storage records, and the storage time can reach more than 48 hours;
※The door lock has the function of opening the door;
※The impact resistance of the lock is strong and must not be less than 250 kg;
※ The whole system can work normally for more than 6 hours under the condition of total power failure;
※The system has anti-vandal function;
The functions that banks must have in order to interlock doors
※Double door interlock function: The two doors of the bank vault and the business hall have the function of interlocking linkage under the control of the system controller. When one of the doors is opened, the other door is absolutely prohibited from being opened.
※ Anti-tailing function: Through the linkage interlocking door intelligent system, other personnel can be prevented from trailing into the bank hall or vault.
※ Tamper alarm function: When someone deliberately destroys various access control facilities (such as controllers, card readers, etc.), the system will automatically generate an alarm signal.
※ Alarm linkage function: When the alarm system generates an alarm signal, the two doors of the bank business hall or the vault are forcibly closed at the same time. Only when the alarm is released, the bank control center is closed by software, and the door can be opened normally.
※Emergency double-opening and double-closing function: When the cash box is transported in the business hall or the vault in the morning or evening, or in a very urgent situation (such as fire, gas, etc.), press the emergency switch button to realize the double door automatic opening. Or close.
※Not closed door prompt function: When any door opening time exceeds the specified limit (usually set to 0-255 seconds) and is not closed or false lock, the live buzzer or management host will have an alarm prompt.
※ Duress code alarm function: If the card holder opens the door while being held, if you enter the duress password at the same time as swiping (or entering the fingerprint), an alarm signal will be sent to the control center when the door is opened.
※Doka opening function: Multi-card opening function means that when entering the business hall or vault, the system can take multiple cards to effectively open the door, that is, after opening a door, more people need to identify the identity effectively within the specified time. Only then can open.
Hubungi kami

Author:

Ms. Yanjun Chen

Phone/WhatsApp:

+8613602572892

Produk populer
You may also like
Related Categories

Email ke pemasok ini

Subjek:
Email:
Pesan:

Your message must be betwwen 20-8000 characters

Rumah

Product

Phone

Tentang kami

Permintaan

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Kirim