Guangdong Zecheng Intelligent Technology Co., Ltd

quentin@zecheng.com.cn

86-0769-39020536

Rumah> Blog> Talking about the construction and installation requirements of access control

Talking about the construction and installation requirements of access control

May 26, 2023
According to the electrical design, construction specifications, procedures and standards issued by the relevant departments of the State in recent years, based on summarizing the design and construction experience of the city's technical defense projects over the past few years, the technology of new technologies and new products based on the development of technical protection technologies was combined. In accordance with the requirements of serving the society and users, the following standards have been formulated.

First, the technical requirements of indoor wiring

Indoor wiring is not only required to be safe and reliable, but also to make the line layout reasonable, neat, and securely installed. The technical requirements are as follows:

The use of wire, the rated voltage should be greater than the operating voltage of the line; the insulation of the wire should be consistent with the installation of the line and the laying of environmental conditions. The cross-sectional area of ​​the conductor should meet the requirements of power supply and mechanical strength.

Wiring should be avoided when wiring. Unless joints are available, their joints must be crimped or welded. Wire connections and branches should not be subjected to mechanical forces.

Wiring is installed horizontally or vertically within the building. The wiring shall be protected by casing (plastic or iron pipe, according to the technical requirements of the indoor wiring), and the metal wire hose may be used for the ceiling wiring, but it shall be fixed securely and beautifully.

The signal line must not be parallel to the high-power power line, and it must not be worn in the same pipe. If it is limited by the environment, if you want to run parallel, you must keep away from more than 50CM.

The AC power supply of the alarm control box shall be routed separately and must not be in the same pipe as the signal line and the low voltage DC power line. The installation of the AC power line shall comply with the electrical installation standards.

The alignment of the alarm control box to the ceiling requires that the casing be embedded in the wall or protected by iron pipes to improve the anti-theft performance of the anti-theft system.

Second, the indoor piping technical requirements :

There are two kinds of wire harnesses, clear and slow, with a horizontal, vertical and neat appearance. Dark piping requires short lines, unobstructed flow, and low elbows.

The choice of line pipe, according to the design choice of pipe types and specifications, if not specified, according to the total area of ​​the wire through the line pipe (with skin), no more than 70% of the pipe cross-sectional area of ​​the hole for the selection.

To facilitate pipe threading and maintenance, when the length of the pipe exceeds the following values, a junction box or cable box shall be installed in the middle, and the position shall be convenient for threading.

(1) When the length of the pipe exceeds 40 meters and there is no bending;

(2) Whenever the length exceeds 25 meters, there is a bend;

(3) When each length exceeds 15 meters and there are two bends;

(4) When each length exceeds 10 meters and there are three bends;

The fixing of the line pipe, the line pipe should be fixed clip every more than 1.5 meters at the corner or straight line distance.

The bend radius of the wire conduit shall comply with the provisions of the bend radius of the cable that is passed through.

Pipes with trachoma, cracks, and large deformations are prohibited from being used in wiring work.

The connection of the line pipe should be sleeved or buckled.

For the pipe laid vertically, according to the size of the cross section of the wire, a fixed threaded terminal box is added every 10-20 meters, and the wire is fixed in the box with an insulated clamp. The thicker the wire, the fixed point The shorter the distance.

In the vertical nozzle that does not enter the box (box), after the wire is pierced, the nozzle should be sealed.

The junction box or junction box should be fixed with no less than three screws.

Connection box and pipe connection should be added cup comb.

Junction box or junction box should be covered.

The branch of the line pipe should be added to the junction box. III. Installation requirements for space detectors :

The space probe installation should meet the requirements of the technical specification.

The detector should be installed with a tamper-proof function for 24 hours to prevent man-made damage.

The detector should be installed so that small animals, such as rats, can be prevented from crawling and approaching.

The detector should be mounted on a sturdy, non-vibrating wall, secured with 2-3 screws.

The detector should be installed so that there should be no obstructions in the front detection range.

Fourth, magnetic switch installation technical requirements :

The installation of magnetron switches should be firm, orderly and aesthetically pleasing to the inside of the door to prevent damage.

The distance between the fixed and movable components of the magnetron switch should be less than the following:

(1), wooden magnetic switch and iron magnetic switch should be less than 5mm.

(2) The magnetic switch of the rolling gate should be less than 20mm.

Fifth, the control box installation technical requirements :

The installation of the control box shall comply with the requirements of the technical specification.

The control box should be fixed with no less than three screws to ensure firmness. The choice of location should be concealed. To prevent damage, the operation of the control box must be remotely controlled. The remote control switch should be installed away from the control box. The tamper function must be provided and protected by the door magnet. If the remote control switch is used with a password switch, it should be misplaced. Three passwords trigger the alarm function.

The control box should be equipped with tamper-proof function, and should be alarmed whenever it is disassembled.

The AC of the control box shall be introduced without the switch. If the switch is to be used, it shall be installed inside the control box. The AC power cord shall be routed through the tube, and it shall not be put in the same tube with other wires.

The lead wire of the control box is protected from the control box to the shed by iron pipes. The iron pipe and the control box are connected by double nuts.

The installation of the power box should be more than 2 meters above the ground, and should be firm, beautiful, and safe.
Hubungi kami

Author:

Ms. Yanjun Chen

Phone/WhatsApp:

+8613602572892

Produk populer
You may also like
Related Categories

Email ke pemasok ini

Subjek:
Email:
Pesan:

Your message must be betwwen 20-8000 characters

Rumah

Product

Phone

Tentang kami

Permintaan

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Kirim